ECDA is a four step process involving the integration and analysis of data from multiple surveys and field examinations with the pipeline’s physical characteristics and operating history. |
|
ECDA (External Corrosion Direct Assessment) |
|
Reference:- ANSI/NACE Standard RP0502-2002 Item No. 21097 |
|
Note:- |
|
Considerable information from the archives of PIM/DCVG/APRT Group were made available to the sub committee producing the NACE Standard. |
|
The NACE specification characterises, on pg 12 table 2, DCVG with ACVG. These are two totally different technologies and should not be considered the same which is what the table does. |
|
A SIMPLE EXPLANATION |
|
When introducing the ECDA concept into your company you will have to read and digest the complete NACE RP0502-2002 recommended document. It is not easy to read and understand. To simplify the introduction of ECDA, DCVG have introduced an ECDA Procedure Manual that sets out all the steps, instructions and reporting procedures necessary to satisfy Government Inspectors. |